Featured Application Note:
Quantitative LC-MS Analysis of 14 Benzodiazepines in Urine Using TraceFinder Software and High Resolution Accurate Mass
By Xiang He, Marta Kozak, Thermo Fisher Scientific

This study highlights new, easy-to-use routine quantitation software for LC-MS analysis with the Exactive high performance benchtop Orbitrap mass spectrometer.

Sample Prep

Detection and Identification of Gulf Oil Dispersants (COREXIT® 9527 and 9500) by GC/MS and LC/MS/MS
Sky Countryman, Matthew Trass, Seyed Sadjadi, and Jeff Layne, Phenomenex

In an effort to contain the largest oil spill in United States history, nearly a million gallons of dispersant have been pumped into the Gulf of Mexico. Unfortunately, very little is known about the impact of these dispersants on humans, wildlife, and the environment. In this technical note we show how GC/MS with Zebron™ ZB-WAXPLUS™ GC columns can be used to detect COREXIT 9527 directly from seawater. To improve GC/MS stability, a cleanup procedure using the Strata™-X-A sorbent is used to virtually eliminate matrix interferences.


LC/HPLC
Agilent 1260 Infinity SFC/MS Solution
Melissa Dunkle, Gerd Vanhoenacker, Frank David, and Pat Sandra Research Institute for Chromatography and Martin Vollmer, Agilent Technologies

The applicability of Supercritical Fluid Chromatography (SFC) can be substantially enhanced by coupling SFC to Mass Spectrometric detection (MSD). In this Technical Overview, two instrument configurations are described that can be used to connect the Agilent 1260 Infinity Analytical SFC to a mass spectrometer either using an atmospheric pressure chemical ionization (APCI) or an electrospray (ESI) source.

High Speed Analysis of Pesticides
Dr. Silvia Marten and Mareike Naguschewski, KNAUER, Germany

This application note describes a very fast gradient HPLC method for the simultaneous determination of nine pesticides commonly used in agriculture. The high speed and reliability of this method using the KNAUER PLATINblue HPLC/UHPLC system make it well-suited for routine analysis. Reduction of analysis time to less than 2 min is achieved by employing BlueOrchid C18 column with 1.8 µm particles.

Improved LC/MS/MS Analysis of Gabapentin in Plasma using a Kinetex® 2.6 µm Core-Shell C18 Column following Protein Precipitation
Matthew Trass, Jeff Layne, & Phillip J. Koerner, Phenomenex

A simple and fast method for the analysis of gabapentin in plasma has been developed over the concentration range 0.5 to 25 μg/mL, which covers the commonly accepted therapeutic levels in patient samples. The LC/MS/MS analysis of gabapentin in plasma is achieved in less than 2 minutes using a Kinetex core-shell column following protein precipitation for sample clean up.

ACQUITY UPLC I-Class: Maximizing the Performance of a Bioanalysis Assay with a Low-Carryover Autosampler
Paul Rainville and Joanne Mather, Waters Corporation

This work demonstrates the extremely low carryover characteristics of the Waters ACQUITY UPLC® I-Class System, which important for maximizing the performance of bioanalytical assays of low-exposure medicines.


LC/HPLC
Automated Extraction and Cleanup of Toxaphene in Soils, Sediment and Fish
Phillip Bassignani, FMS, Inc.

Toxaphene does not occur naturally in the environment. It is widely found in the environment, mainly as a result of past releases to air, water, and soil through its use as a pesticide. The forms of toxaphene commonly found in the environment are a gas in the atmosphere, a solid in soils and sediment, and in surface and groundwater. Toxaphene found near hazardous waste sites is usually a solid.

misc
Agarose Characterization with high temperature
Wyatt Technology

This note describes the characterization of agarose by size-exclusion chromatography (SEC) and multi-angle light scattering (MALS) at an elevated temperature.
To advertise or have an application note inserted, contact:

Lee Noyes
+44 1244 629315 | Email

Lindsay Jones
+44 1244 629316 | Email




You are subscribed to %%list.name%% as %%emailaddr%%. Click here to unsubscribe or edit your member profile.

To ensure delivery to your Inbox, please add %%email.list%% to your address book. If you need help doing this, click here.

Advanstar Communications provides certain customer contact data (such as customers' names, addresses, phone numbers and e-mail addresses) to third parties who wish to promote relevant products, services and other opportunities which may be of interest to you. If you do not want Advanstar Communications to make your contact information available to third parties for marketing purposes, simply call (toll free) 1-866-529-2922 at any time, or fax us at 1-218-740-6417. Outside the U.S., please phone 1-218-740-6395. Contact us by mail at Advanstar Communications Inc., Bridgegate Pavilion, 4A Chester Business Park, Wrexham Road, Chester, CH4 9QH, UK.