LCGC Europe Single Sponsored Application Note Alert
Having trouble viewing this email?
Click here
February 2014


Pesticide Testing
Single–Run Analysis of PBDEs Including BDE–209
Kory Kelly, Kristen Parnell, and Kali Tudela
A new HRGC–HRMS method and technology that provides quantitation of toxic PBDE congeners with short run times and includes the quantitation of BDE-209 in a single analytical run. Read More
Improved Inertness and Detection for Semi-Volatiles Methods
Kory Kelly, Kristen Parnell, and Kali Tudela
This study explores the inertness of leading GC columns used for semi-volatiles testing and presents the advantages afforded by using columns designed and QC tested specifically for response and peak shape of active compounds. Read More
Analyzing EPA 8270D with Application-Specific GC Columns
Kory Kelly
A GC–MS method analyzing base/neutral/acids (BNAs) is presented using the Zebron™ ZB-SemiVolatiles GC column. Specific attention is paid to the behavior of typically poor performing compounds like pyridine and PCP. Read More
Leveraging High-Temperature Gas Chromatography for DRO Analysis
Kory Kelly and Kali Tudela
Considerations should be taken to ensure reproducible results over repeated injections of heavy compounds. This technical note discusses advantages of using a GC column stable to 430°C when analyzing DROs. Read More
LC–MS–MS and GC–MS Analysis of Triazine Herbicides
Kory Kelly and Kali Tudela
Two methods are presented for triazine herbicides analysis in drinking water (EPA Method 536) and wastewater (EPA Method 619) exhibiting resolution and sensitivity improvements as well as time savings. Read More

Pesticide Testing
Reproducible, Aqueous–Stable Separations for Distilled Spirit Analysis
Sky Countryman and Kory Kelly
Distilled spirit analysis with traditional PEG phases presents challenges that can result in poor reproducibility and decreased lifetime. Improved stability to repeated aqueous injections is presented with an optimized WAX phase. Read More
Optimized Multi–Residue Pesticide Screening by GC–MS
Sky Countryman and Kory Kelly
An optimized GC–MS method for multi-residue pesticide screening is presented. Application-specific selectivity is explored, displaying increased resolution of critical compounds versus standard 5 ms type phases. Read More

Pesticide Testing
Improved High-Temp SimDist with Metal GC Columns
Kory Kelly, Sky Countryman, Chris Fernandez, and Ngoc Nguyen
This method presents improved efficiency and resolution for simulated distillation testing, such as ASTM methods D6352 and D7169. Range is also extended from C100 to C120 while still meeting all system suitability requirements. Read More

Pesticide Testing
Attaining Sharper Peak Shape and Higher Sensitivity in GC
Matthew Trass and Sky Countryman
This guide presents two simple optimizations GC analysts can perform to more easily meet method detection limits (MDL) requirements. Solvent focusing and proper GC column selection are discussed. Read More
GC Troubleshooting Tips & Tricks
Phenomenex
GC troubleshooting and preventative maintenance are leading causes of lab downtime. Learn helpful tips and tricks to quickly isolate and solve troubleshooting problems with this guide. Read More